Link Search Menu Expand Document

Data Aquisition

  • Electric consumption in kWh
  • hourly values required, 15min values desirable

Calculations

  • hourly sum of electric consumption (15min could be done as well, calculation will take longer )
  • remove negative, invalid values
  • remove upper outliers
    • Assumption max. fuse 40 ampere (average in single family houses [2])
    • this results in continuous power 9.2 kW
    • over 24h = approx. 221 kWh max. consumption per day
    • Everything above is very unlikely…
  • calculate season out of date (for later filtering)
  • calculate sum per day
  • calculate minimum per day (standby-losses)
  • calculate rolling averages for usage
  • calculate rolling minimum for standby-losses
  • calculate standby-share value with total energy consumtion and standby-average of the rolling minimum
  • calculate typical houshold consumption for comparison. Formulas and values from [1]

References

[1] Nipkov, J. (2013). Typischer Haushalt-Stromverbrauch. Schlussbericht. Bundesamt für Energie (BFE). https://www.aramis.admin.ch/Default.aspx?DocumentID=61764
[2] Sattler, M. et al. (2020). 16 A-Gebäude: Stromnetzstabilisierung und Nutzerbeeinflussung durch elektrische Leistungsbegrenzung für Gebäude. Bundesamt für Energie (BFE). https://www.aramis.admin.ch/Texte/?ProjectID=40160